• Title of article

    Experiments for entrainment rate of droplets in the annular regime

  • Author/Authors

    Lopez de Bertodano، نويسنده , , M.A. and Assad، نويسنده , , A. and Beus، نويسنده , , S.G.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    15
  • From page
    685
  • To page
    699
  • Abstract
    Two-fluid model predictions of film dryout in annular flow are limited by the uncertainties in the entrainment rate of droplets from the liquid film. The main cause of these uncertainties is the lack of separate effects experimental data in the range of the operating conditions in industrial applications. ter and Freon-113 entrainment rate data have been obtained in 10 mm tubes using the double film extraction technique. These experiments have been scaled to approach high-pressure steam–water flow conditions. The effects of surface tension and density ratio, missing from most previous data sets, have been systematically tested. trainment rate mechanism is scaled by the Kelvin–Helmholtz instability at the film surface. Based on this analysis and the new data, a new correlation is proposed that is valid for low-viscosity fluids in small ducts in the ripple-annular regime.
  • Keywords
    Atomization , Entrainment rate , Droplets , Liquid film , Two-fluid model , Film extraction , FREON , Annular flow
  • Journal title
    International Journal of Multiphase Flow
  • Serial Year
    2001
  • Journal title
    International Journal of Multiphase Flow
  • Record number

    1403620