Title of article
Air–water two-phase flow and heat transfer in a plate heat exchanger
Author/Authors
Vlasogiannis، نويسنده , , P and Karagiannis، نويسنده , , G and Argyropoulos، نويسنده , , P and Bontozoglou، نويسنده , , V، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2002
Pages
16
From page
757
To page
772
Abstract
A plate heat exchanger is tested under two-phase flow conditions by using an air/water mixture as the cold stream. Visual observations recorded by a high-speed video camera lead to the construction of a flow regime map. The heat transfer coefficient of the air/water stream is measured as a function of air and water superficial velocities. The flow regime with a gas-continuous phase covering the core of the channel and liquid flowing in the form of rivulets inside the furrows shows particularly favorable heat transfer characteristics.
Keywords
Plate and Frame heat exchanger , air-water flow , Flow regime map , Coefficient of heat transfer
Journal title
International Journal of Multiphase Flow
Serial Year
2002
Journal title
International Journal of Multiphase Flow
Record number
1403841
Link To Document