Title of article
Experimental investigation and theoretical modeling of liquid entrainment in a horizontal tee with a vertical-up branch
Author/Authors
Welter، نويسنده , , K.B. and Wu، نويسنده , , Q. and You، نويسنده , , Y. and Abel، نويسنده , , K. and McCreary، نويسنده , , D. and Bajorek، نويسنده , , S.M. and Reyes Jr، نويسنده , , J.N.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2004
Pages
34
From page
1451
To page
1484
Abstract
This article describes a comprehensive literature review of liquid entrainment in horizontal pipes with vertical-up branches. Deficiencies in the available data and correlations were identified. The Air–water Test Loop for Advanced Thermal–hydraulic Studies (ATLATS) was constructed and entrainment onset and steady-state data were collected for a wide range of flow conditions. Using new insights gained from experimental testing, the authors developed a model for predicting the onset of entrainment and steady-state entrainment rate. Previously published correlations, along with the new model, are compared against all available data. The new model shows very good agreement with the onset data, but is not very good at predicting branch quality at high liquid flow rates.
Keywords
LOCA , Liquid entrainment , Advanced reactor , Phase separation , Tees
Journal title
International Journal of Multiphase Flow
Serial Year
2004
Journal title
International Journal of Multiphase Flow
Record number
1409634
Link To Document