• Title of article

    Influence of surface tension implementation in Volume of Fluid and coupled Volume of Fluid with Level Set methods for bubble growth and detachment

  • Author/Authors

    Zahir Albadawi، نويسنده , , A. and Donoghue، نويسنده , , D.B. and Robinson، نويسنده , , A.J. and Murray، نويسنده , , D.B. and Delauré، نويسنده , , Y.M.C.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    18
  • From page
    11
  • To page
    28
  • Abstract
    A simple coupled Volume of Fluid (VOF) with Level Set (LS) method (S-CLSVOF) for improved surface tension implementation is proposed and tested by comparison against a standard VOF solver and experimental observations. A CFD Open source solver library (OpenFOAM®) is used for the VOF method, where the volume fraction is advected algebraically using a compressive scheme. This method has been found not to be suitable for problems with high surface tension effects and it is extended by coupling it with a LS method which is used to calculate the surface tension and the interface curvature. Two test cases; a circular bubble at equilibrium and a free bubble rise, are studied first to examine the accuracy of the S-CLSVOF method. The problem of 3D axi-symmetrical air bubble injection into quiescent water using different volumetric flow rates is then considered to assess the method under challenging capillary dominant conditions. An experimental study has been performed to validate the numerical methods with reference to the geometrical characteristics of the bubble during the full history of formation. The exponential power law controlling the detachment process is investigated. In addition, the influence of the static contact angle imposed at the rigid wall is considered. The results have shown that the coupling code (S-CLSVOF) improves the accuracy of the original VOF method when the surface tension influence is predominant. The two methods provide similar results during the detachment stage of the process due to the large increase of the gas inertia effect. Finally, the static contact angle boundary condition was shown to allow accurate modeling provided that the imposed static contact angle is less than the minimum instantaneous values observed experimentally.
  • Keywords
    Bubble detachment , Volume-of-Fluid , Bubble growth , Static contact angle , Gas–liquid flow , Level Set , Coupled VOF with LS
  • Journal title
    International Journal of Multiphase Flow
  • Serial Year
    2013
  • Journal title
    International Journal of Multiphase Flow
  • Record number