Title of article :
Pre- and post-test calculations to natural circulation experiments at the integral test facility ISB-VVER using the thermalhydraulic code ATHLET
Author/Authors :
KREPPER، ECKHARD نويسنده ,
Issue Information :
دوهفته نامه با شماره پیاپی سال 1999
Pages :
-340
From page :
341
To page :
0
Abstract :
In 1995 at the integral test facility ISB-VVER in Elektrogorsk near Moscow natural circulation experiments were performed, which were scientifically accompanied by the Forschungszentrum Rossendorf. These experiments were the first of this kind at a test facility, which models VVER-1000 thermalhydraulics. Using the code ATHLET which is being developed by ʹGesellschaft fur Aniagen und Reaktorsicherheitʹ, pre- and post-test calculations were done to determine the thermalhydraulic events to be expected and to define and tune the boundary conditions of the test. The conditions found for natural circulation instabilities and cold leg loop seal clearing could be confirmed by the tests. Besides the thermalhydraulic standard measuring system, the facility was equipped with needle shaped conductivity probes for measuring the local void fractions. © 1999 Elsevier Science S.A. All rights reserved.
Keywords :
Boiling channels , Singularity theory , Normal form , Hysteresis variety , Universal unfolding