Title of article
The origin of oxygen dependence in a potentiometric CO2 sensor with Li-ion conducting electrolytes
Author/Authors
Park، نويسنده , , C.O and Lee، نويسنده , , C and Akbar، نويسنده , , S.A and Hwang، نويسنده , , J، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
7
From page
53
To page
59
Abstract
When the electrochemical cell arrangement of type III, O2, CO2, Au, Li2CO3∣Li+ conductor∣O2, reference (aLi2O=constant) is used to measure the CO2 concentration in air, the emf should depend only on the logarithmic concentration of CO2. In reality, however, the sensor response is also affected by the oxygen present in the environment. The oxygen dependence of the CO2 sensing electrochemical cell originates from an influence of electronic conduction in the electrolyte. The theoretical change of emf with oxygen pressure, which is predicted from the modified emf-equation for the electrochemical cell with a mixed conducting electrolyte, agrees well with the measured emf change.
Keywords
Carbon dioxide sensor , Electrochemical sensor , Mixed conduction , Oxygen dependence , Li-ion conductor