• Title of article

    4-Allyloxy-7-aminocoumarin as a fluorescent carrier for optical sensor preparation and indole-3-acetic acid assay

  • Author/Authors

    Jiao، نويسنده , , Chen-Xu and Niu، نويسنده , , Cheng-Gang and Chen، نويسنده , , Li-Xin and Shen، نويسنده , , Guo-Li and Yu، نويسنده , , Ru-Qin، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    8
  • From page
    176
  • To page
    183
  • Abstract
    The synthesis of a fluorescence carrier, 4-allyloxy-7-aminocoumarin (AAC) having terminal double bond for preparing an optical chemical sensor has been described. The carrier is covalently immobilized on a quartz glass plate surface treated with a silanizing agent to prevent its leakage. The AAC based sensor can be applied for indole-3-acetic acid (IAA) assay by fluorescence quenching. The quenching process and the basis of quantitative assay were discussed. The experimental conditions for IAA assay has been optimized. The AAC sensor shows a linear response toward IAA in the concentration range of 1.0×10−6 to 1.0×10−3 mol l−1, with a detection limit of 9.0×10−7 mol l−1 at pH 7.0. The AAC sensor has good selectivity for IAA over many inorganic and organic compounds.
  • Keywords
    Optical sensor , Indole-3-acetic acid , Fluorescence quenching , Coumarin derivative
  • Journal title
    Sensors and Actuators B: Chemical
  • Serial Year
    2003
  • Journal title
    Sensors and Actuators B: Chemical
  • Record number