• Title of article

    Results on the reliability of silicon micromachined structures for semiconductor gas sensors

  • Author/Authors

    Gràcia، نويسنده , , I and Santander، نويسنده , , J and Cané، نويسنده , , C and Horrillo، نويسنده , , M.C and Sayago، نويسنده , , I and Gutierrez، نويسنده , , J، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2001
  • Pages
    7
  • From page
    409
  • To page
    415
  • Abstract
    Thin film semiconductor gas sensors fabricated on thermally isolated silicon substrates have been proposed as good alternative to thick film devices that are on the market as they show low power consumption. However, for their industrial success, it is necessary to assess good yield and high reliability for maintaining the functionality of the device during a long period of time. In this paper, a set of thermo-mechanical tests has been applied to gas sensors based on silicon micromachined structures with dielectric membranes. The aim of the tests is to determine the survivability of the devices under aggressive conditions of use. The tests have been carried out on two specific structures, a single Si3N4 membrane; and the same device that also includes a silicon plug below the sensor active area. Results are compared as a tool for improving the structure in the future.
  • Keywords
    Microelectronic gas sensor , Micromachined structures , survivability , Reliability
  • Journal title
    Sensors and Actuators B: Chemical
  • Serial Year
    2001
  • Journal title
    Sensors and Actuators B: Chemical
  • Record number