Title of article :
AC vs. DC electrophoretic deposition of hydroxyapatite on titanium
Author/Authors :
Ozhukil Kollath، نويسنده , , V. and Chen، نويسنده , , Q. and Closset، نويسنده , , R. and Luyten، نويسنده , , AGMA J. M. TRAINA، نويسنده , , K. and Mullens، نويسنده , , S. and Boccaccini، نويسنده , , A.R. and Cloots، نويسنده , , R.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
7
From page :
2715
To page :
2721
Abstract :
In this study, electrophoretic deposition (EPD) of hydroxyapatite (HA) powder on titanium plate was performed using butanol as solvent under direct current (DC) and alternating current (AC) fields. The zeta potential of the suspensions was measured to define their stability and the charge on the particles. Coating thickness was varied by adjusting the voltage and time of deposition. Surface morphology and cross section thickness were studied using scanning electron microscopy and image analysis software. Surface crack density was calculated from the micrographs. The results showed that the samples of similar thickness have higher grain density when coated using AC as compared to DC EPD. This facile but novel test proves the capability of AC-EPD to attain denser and uniform HA coatings from non-aqueous medium.
Keywords :
Electrophoretic Deposition , Alternating current , Hydroxyapatite , Titanium , Biomedical coatings
Journal title :
Journal of the European Ceramic Society
Serial Year :
2013
Journal title :
Journal of the European Ceramic Society
Record number :
1415708
Link To Document :
بازگشت