Title of article :
Electroosmotic flow pumps with polymer frits
Author/Authors :
Zeng، نويسنده , , Shulin and Chen، نويسنده , , Chuan-Hua and Santiago، نويسنده , , Juan G and Chen، نويسنده , , Jing-Ran and Zare، نويسنده , , Richard N and Tripp، نويسنده , , Jennifer A and Svec، نويسنده , , Frantisek and Fréchet، نويسنده , , Jean M.J، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Pages :
4
From page :
209
To page :
212
Abstract :
Electroosmotic flow (EOF) pumps with flow rates on the order of 1 ml/min have been designed and fabricated. These pumps use EOF to propel liquid solutions in a compact system with no moving parts. The pumping chamber is filled with densely packed non-porous silica particles, and the particle bed is held in place using two polymeric porous frits. The pump frame is made of acrylic, the frits are made using UV photopolymerization within the custom-built acrylic frame, and the particles are packed using a novel side-bore packing technology. Platinum wire electrodes on both sides of the pump provide the electric field to drive the flow. Deionized water is used as a working fluid in order to minimize Joule heating and increase thermodynamic efficiency. The maximum flow rates and maximum pressures generated by the pumps are 0.8 ml/min and 2 atm, respectively, at 1.0 kV applied voltage.
Keywords :
Elctroosmotic , PUMP , Large flow rate , Electrokinetic
Journal title :
Sensors and Actuators B: Chemical
Serial Year :
2002
Journal title :
Sensors and Actuators B: Chemical
Record number :
1416873
Link To Document :
بازگشت