Title of article :
Electrochemical H2S sensor with H2SO4 pre-treated Nafion membrane as solid polymer electrolyte
Author/Authors :
Yu، نويسنده , , Chunbo and Wang، نويسنده , , Yujiang and Hua، نويسنده , , Kaifeng and Xing، نويسنده , , Wei and Lu، نويسنده , , Tianhong، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2002
Abstract :
It is reported for the first time that the performance of the electrochemical H2S sensor with the Nafion membrane pre-treated with the concentrated H2SO4 as the solid electrolyte is much more stable than that for the sensor with the Nafion membrane without H2SO4 pre-treatment. The sensitivity of the sensor is about 2.92 μA/ppm. The response time of the sensor is about 9 s. The detection limit is about 0.1 ppm. Therefore, this kind of the electrochemical H2S gas sensor may be desirable for the practical application.
Keywords :
Electrochemical oxidation , Gas sensor , Hydrogen sulfide , solid electrolyte
Journal title :
Sensors and Actuators B: Chemical
Journal title :
Sensors and Actuators B: Chemical