Title of article :
Determination of thallium and cadmium on a chemically modified electrode with Langmuir–Blodgett film of p-allylcalix[4]arene
Author/Authors :
Dong، نويسنده , , Huimin and Zheng، نويسنده , , Hao and Lin، نويسنده , , Lin and Ye، نويسنده , , Baoxian، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
6
From page :
303
To page :
308
Abstract :
A glassy carbon electrode (GCE) coated with Langmuir–Blodgett (LB) film of p-allylcalix[4]arene is described for simultaneous determination of traces of thallium and cadmium in environmental water. The LB film electrode in a 0.1 M KH2PO4 solution shows a linear voltammetric response in the range of 5–250 μg l−1 for thallium and 10–300 μg l−1 for cadmium. The detection limits of thallium(I) and cadmium(II) are estimated to be 1.0 μg l−1 (ca. 5.0 × 10−9 M) and 2.2 μg l−1 (ca. 2.0 × 10−8 M), respectively. Above all, the indium does not respond to this LB film electrode.
Keywords :
Thallium , Cadmium , Langmuir–Blodgett film , Stripping voltammetry , Calixarenes
Journal title :
Sensors and Actuators B: Chemical
Serial Year :
2006
Journal title :
Sensors and Actuators B: Chemical
Record number :
1421261
Link To Document :
بازگشت