Title of article :
Supercritical water oxidation of transformer oil contaminated with PCBs—A road to commercial plant from bench-scale facility
Author/Authors :
Kim، نويسنده , , Kyeongsook and Kim، نويسنده , , KwangSin and Son، نويسنده , , Soon Hwan and Cho، نويسنده , , Jungho and Kim، نويسنده , , Yeong-Cheol، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
10
From page :
121
To page :
130
Abstract :
Polychlorinated biphenyls (PCBs) are one of the eradication compound lists of Stockholm convention. Korea started to analyze the PCBs concentration in high-voltage transformers in June 2004 and is developing PCBs disposing technology. As most of the transformers in Korea were contaminated at very low level of less than 5 ppm, it was decided that SCWO (supercritical water oxidation) process is suitable to treat them. stroying parameters of SCWO process including optimum process temperature, pressure, residence time, and amount of oxidant were studied with a bench-scale facility. Based on these results and simulation, a pilot plant was designed and built to confirm the suggested condition. Recently detail design of a commercial plant was completed based on these results. In this paper, the procedures to scale up the design from a bench-scale facility to a commercial plant and major check points in each stage are introduced.
Keywords :
Transformer Oil , polychlorinated biphenyls (PCBs) , Supercritical water oxidation (SCWO) , Bench-scale facility , Commercial plant , Pilot plant
Journal title :
Journal of Supercritical Fluids
Serial Year :
2011
Journal title :
Journal of Supercritical Fluids
Record number :
1423566
Link To Document :
بازگشت