Title of article
Novel CMM-based implementation of the multi-step method for the separation of machine and probe errors
Author/Authors
Nafi، نويسنده , , Abdelhak and Mayer، نويسنده , , J.R.R. and Wozniak، نويسنده , , Adam، نويسنده ,
Issue Information
فصلنامه با شماره پیاپی سال 2011
Pages
11
From page
318
To page
328
Abstract
Coordinate measuring machines (CMMs) are subject to periodic verification to ensure measurement capability. However, users also need to rapidly diagnose the source of accuracy degradation to guide corrective actions. This paper presents a novel CMM-based implementation of the multi-step method for the separation of machine and reference sphere errors on one side and triggering probe and probe tip errors on the other. The procedure uses multiple redundancy probing of the machineʹs own reference sphere and result in a mathematical system similar to that of the multi-step method. The procedureʹs effectiveness is demonstrated for a variety of stylus lengths and shows its ability to detect changes in lobing errors. A metrological validation is conducted by measuring the errors of the probe and errors of the machine using independent methods.
Keywords
Probe errors , Triggering probe , Multiple redundancy method , Machine errors , Multi-step , coordinate measuring machine , CMM
Journal title
Precision Engineering
Serial Year
2011
Journal title
Precision Engineering
Record number
1429603
Link To Document