Title of article
Measurements of contact potential difference (work functions) of metals and semiconductors surface by the static ionized capacitor method
Author/Authors
Novikov، نويسنده , , Sergey Nikolaevich and Timoshenkov، نويسنده , , Sergey Petrovich، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2003
Pages
11
From page
329
To page
339
Abstract
Electron work functions of several metals (Au, W, Ag, Cu, Mo, Ti, Al) and Si at atmospheric conditions have been measured by the method of the static capacitor with an ionized gap between the electrodes. Results for all samples, excluding Au, Al and Si, conform to reference data with an accuracy of ±1.0%. For samples Au, Al and Si, the electron work function values conform to reference data after short-time heat treatment at atmospheric conditions at 200 °C (for Al) and 600 °C (for Au, Si).
Keywords
surface , POTENTIAL , Work function , Static ionized capacitor
Journal title
Advances in Colloid and Interface Science
Serial Year
2003
Journal title
Advances in Colloid and Interface Science
Record number
1432637
Link To Document