Title of article :
Development of TiO2-supported RuO2 composite-incorporated Ni–P electrodes for amperometric measurement of ethanol
Author/Authors :
Shibli، نويسنده , , S.M.A. and Suma، نويسنده , , N.D. and Dilimon، نويسنده , , V.S.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
7
From page :
139
To page :
145
Abstract :
An electroless Ni–P coating incorporated with TiO2-supported nano-RuO2 was developed as a high performance amperometric ethanol sensor. The electrode was systematically investigated for sensing ethanol in 0.2 M NaOH. The composite electrode exhibited good performance with high anodic current for electrochemical ethanol oxidation. The optimized electrode exhibited a response time of 21 s and a sensitivity of 3.6 μA/(ppm cm2). The incorporation of the catalytic composites in the coating resulted in increased roughness of the coating enhancing the hydroxyl radical adsorption during ethanol oxidation.
Keywords :
Electroless nickel coating , Electrochemical sensor , Mixed oxide composite , Ruthenium dioxide , Ethanol sensor
Journal title :
Sensors and Actuators B: Chemical
Serial Year :
2008
Journal title :
Sensors and Actuators B: Chemical
Record number :
1435284
Link To Document :
بازگشت