Title of article :
Gas sensing by AT-cut quartz crystal oscillator coated with mixed-lipid film
Author/Authors :
Ichinohe، نويسنده , , Shunpei and Tanaka، نويسنده , , Hirokazu and Kanno، نويسنده , , Yoshinori، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
7
From page :
306
To page :
312
Abstract :
AT-cut 9 MHz quartz crystal microbalance (QCM) sensors coated with mixed-lipid films were investigated. Mixed-lipid films on the quartz crystal contributed to the sensitivity elevation of the sensors for VOCs. For example, the sensitivity of a sensor coated with a mixed film (2C12N+C2OH and 2C12N+/PSS) to 1,1,1-trichloroethane is nine times higher than that of a sensor coated with a 2C12N+C2OH film only. The approximate curves were created from the frequency shift curves of the gas sensors. The differential coefficients of the approximate curves at measurement times of 20 and 40 s showed better classification of VOCs.
Keywords :
Approximate curve , AT-cut quartz crystal , Mixed-lipid film , Differential Coefficient , QCM sensor , VOC
Journal title :
Sensors and Actuators B: Chemical
Serial Year :
2007
Journal title :
Sensors and Actuators B: Chemical
Record number :
1436022
Link To Document :