Title of article :
Fiber optic hydrogen detectors containing Mg-based metal hydrides
Author/Authors :
Slaman، نويسنده , , M. and Dam، نويسنده , , B. and Pasturel، نويسنده , , M. and Borsa، نويسنده , , D.M. and Schreuders، نويسنده , , H. and Rector، نويسنده , , J.H. and Griessen، نويسنده , , R.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
8
From page :
538
To page :
545
Abstract :
We report on the implementation of Pd-capped chemo-chromic metal hydrides as a sensing layer in fiber optic hydrogen detectors. Due to the change in optical properties of Mg-based alloys on hydrogen absorption, a drop in reflectance by a factor of 10 is demonstrated at hydrogen levels down to 15% of the lower explosion limit. The switching takes place in only a few seconds. Comparing Mg–Ni and Mg–Ti based alloys, we find that the latter has superior optical and switching properties. Using a 50 nm thick Mg70Ti30 film capped with a 30 nm Pd catalytic layer as the sensing layer, we report on the sensitivity of the fiber optic detector for hydrogen both in argon and oxygen, the temperature behavior and the reversibility.
Keywords :
Fiber optic hydrogen detector , metal hydride , Switchable mirror , Absorbing light , Mg–Ti , Mg–Ni
Journal title :
Sensors and Actuators B: Chemical
Serial Year :
2007
Journal title :
Sensors and Actuators B: Chemical
Record number :
1436102
Link To Document :
بازگشت