Abstract
A potentiometric biosensor based on bovine serum albumin (BSA) embedded surface modified polypyrrole has been developed for the quantitative estimation of urea in aqueous solution. The enzyme, urease (Urs), was covalently linked to free amino groups present over the BSA embedded modified surface of the conducting polypyrrole film electrochemically deposited onto an indium–tin-oxide (ITO) coated glass plate. The biosensor has been characterized by UV–visible, infrared spectroscopy and SEM. Potentiometric and spectrophotometric response of the enzyme electrode (Urs/BSA-PPy/ITO) were measured as a function of urea concentration in Tris–HCl buffer (pH 7.0). It has been found that the electrode responds to low urea concentration with wider range of detection. The electrode showed a linear response range of 6.6 × 10−6 to 7.5 × 10−4 M urea. The response time is about 70–90 s reaching to a 95% steady-state potential value and 75% of the enzyme activity is retained for about 2 months. These results indicate an efficient covalent linkage of enzyme to free amino groups of the BSA molecules over the surface of polypyrrole film, which leads to high enzyme loading, an increased lifetime stability of the electrode and an improved wide range of detection of low urea concentration in aqueous solution.
Keywords
Biosensor , BSA , Enzyme , urea , Peptide linkage , Polymer
Journal title
Sensors and Actuators B: Chemical
Serial Year
2008
Journal title
Sensors and Actuators B: Chemical
Record number
1436488
Link To Document