• Title of article

    Gas sensing by AT-cut quartz crystal oscillator coated with mixed-lipid film

  • Author/Authors

    Ichinohe، نويسنده , , Shunpei and Tanaka، نويسنده , , Hirokazu and Kanno، نويسنده , , Yoshinori، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    7
  • From page
    306
  • To page
    312
  • Abstract
    AT-cut 9 MHz quartz crystal microbalance (QCM) sensors coated with mixed-lipid films were investigated. Mixed-lipid films on the quartz crystal contributed to the sensitivity elevation of the sensors for VOCs. For example, the sensitivity of a sensor coated with a mixed film (2C12N+C2OH and 2C12N+/PSS) to 1,1,1-trichloroethane is nine times higher than that of a sensor coated with a 2C12N+C2OH film only. The approximate curves were created from the frequency shift curves of the gas sensors. The differential coefficients of the approximate curves at measurement times of 20 and 40 s showed better classification of VOCs.
  • Keywords
    Mixed-lipid film , VOC , Approximate curve , Differential Coefficient , AT-cut quartz crystal , QCM sensor
  • Journal title
    Sensors and Actuators B: Chemical
  • Serial Year
    2007
  • Journal title
    Sensors and Actuators B: Chemical
  • Record number

    1438814