    Highly efficient dual-channel cytometric-detection of micron-sized particles in microfluidic device

  • Author/Authors

    Mu، نويسنده , , Canjun and Zhang، نويسنده , , Feiling and Zhang، نويسنده , , Zhiyi and Lin، نويسنده , , Min-Jie Cao، نويسنده , , Xudong، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    8
  • From page
    402
  • To page
    409
  • Abstract
    To demonstrate the ability to efficiently count and identify suspended micron-sized particles by simultaneously detecting their fluorescence emission and light scattering in microfabricated channel, a compact configuration that used a polydimethylsiloxane (PDMS) microfabricated channel as interrogation component, hydrodynamic focusing for particle control, and a simple free-space optical setup for signal detection, was accordingly developed. Subsequently, a quantitative count of 1.013 μm diameter fluorescently labeled beads in suspension was implemented in a microfluidic device employing both fluorescence emission and light scattering at average particle throughput ranging from 83 to 416 particles/s. As a result, the detection efficiencies above 88% for both signals and correlation percentages above 97% between them were routinely achieved. In addition, it was shown that effective differentiation of 1.013 μm fluorescently labeled beads from various unlabeled beads in mixed populations of high mixing ratios had been successfully realized in this microfluidic-device-based instrumentation. Finally, the demonstrated system was used to detect fluorescein isothiocyanate (FITC) labeled nonpathogenic bacteria of Escherichia coli (E. coli) DH5α. The results showed the detection efficiencies above 89.7% for fluorescence emission and 94.5% for light scattering signals, and a correlation of 94.9% between the two signals at an average throughput of 350 cells/s have been obtained. As a comparison, the detection accuracies of the dual-channel cytometric detection of the FITC-labeled E. coli DH5α cells in the microfluidic device are approximately 84.3% and 88.8% for fluorescence emission and light scattering respectively when compared against a manual cell count using a haemocytometer as a standard.
  • Keywords
    Microfabricated channel , Cytometric analysis , High throughput measurement , Dual channel detection
  • Journal title
    Sensors and Actuators B: Chemical
  • Serial Year
    2011
  • Journal title
    Sensors and Actuators B: Chemical
  • Record number

    1439001