Title of article :
Hydrogen detection using platinum coated graphene grown on SiC
Author/Authors :
Chu، نويسنده , , Byung Hwan and Lo، نويسنده , , C.F. and Nicolosi، نويسنده , , Justin Sueun Chang، نويسنده , , C.Y. and Chen، نويسنده , , Victor and Strupinski، نويسنده , , W. and Pearton، نويسنده , , S.J. and Ren، نويسنده , , F.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Pages :
4
From page :
500
To page :
503
Abstract :
The characteristics of hydrogen detection using epitaxial graphene covered with platinum are reported. The multi-layered graphene was grown by chemical vapor deposition (CVD) on a Si-polar 4H-SiC substrate. Surface morphology was characterized by scanning electron and atomic force microscopy. Current–voltage measurements and real-time monitoring of the current flow through the graphene/platinum device were used to confirm the response to hydrogen gas. The background temperature was varied from room temperature to 175 °C in order to measure the activation energy of hydrogen detection.
Keywords :
Epitaxial graphene , CVD graphene , Hydrogen sensor , Platinum , SiC
Journal title :
Sensors and Actuators B: Chemical
Serial Year :
2011
Journal title :
Sensors and Actuators B: Chemical
Record number :
1439687
Link To Document :
بازگشت