Title of article :
One-step sensing lead in surface waters with screen printed electrode
Author/Authors :
Fang، نويسنده , , Hai-Lin and Zheng، نويسنده , , Hu-Xiang and Ou، نويسنده , , Mei-Yun and Meng، نويسنده , , Qi and Fan، نويسنده , , Da-He and Wang، نويسنده , , Wei، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2011
Abstract :
The paper described a method for one-step sensing lead in surface waters. A screen printed carbon electrode was coupled with a paper disk impregnated with buffer and reagents including an internal standard Zn(II) and plating solution Bi(III), when the sample was added on the surface of electrode, it could be applied to run a single-step assay for lead detection in surface waters. Mechanism of internal standardization was discussed and the calibration constant was deduced. Detection of trace lead (ppb level) in 10 μL sample was performed. Surface waters with spiked Pb(II) were tested, the linear range was to 100 ppb, and 5–50 ppb Pb(II) was determined, the results were consistent with that by ICP-AES.
Keywords :
Surface water , Pb detection , One-step electrochemical detection , Internal standard
Journal title :
Sensors and Actuators B: Chemical
Journal title :
Sensors and Actuators B: Chemical