Title of article :
Performance of potentiometric oxygen sensors with LSM-GDC composite electrode in liquid LBE at low temperatures
Author/Authors :
Lim، نويسنده , , J. and Manfredi، نويسنده , , G. and Mariën، نويسنده , , A. and Van den Bosch، نويسنده , , J.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
7
From page :
1048
To page :
1054
Abstract :
Potentiometric oxygen sensors integrated with LSM (strontium-doped lanthanum manganite)-GDC (gadolinium-doped ceria) composite electrode have been developed for use in liquid LBE at low temperatures. The performance of these sensors has been evaluated in oxygen saturated LBE in the temperature range of 200–400 °C. Their performance was compared with that for platinum electrode and Bi/Bi2O3 electrode. The sensor with LSM-GDC composite electrode performed well down to 200 °C by using a voltmeter with high input resistance (>10 GΩ), while those with platinum electrode and Bi/Bi2O3 electrode showed significant deviations at 200 °C.
Keywords :
MYRRHA , Lead-bismuth eutectic , Potentiometric oxygen sensor , LSM-GDC composite electrode
Journal title :
Sensors and Actuators B: Chemical
Serial Year :
2013
Journal title :
Sensors and Actuators B: Chemical
Record number :
1443089
Link To Document :
بازگشت