Title of article
Comparison of destructively and rinsing gained samples to determine TVC of pig carcasses by bioluminescence
Author/Authors
H.-D. Werlein، نويسنده , , H.-D.، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2001
Pages
4
From page
165
To page
168
Abstract
A rinsing-technique with a spraying gun in combination with the ATP-bioluminescence for determining the microbial load was investigated. In each case 3.8-cm2 pig-rind was rinsed with buffered peptone water using a modified sprinkle-bottle. The sample-suspensions were gathered in a one-way syringe and sent through a filter cascade consisting of a coarse filter in order to remove bigger particles and a sensitive filter to attach the micro-organisms as well as somatic cells. This procedure was followed by an extraction of the ATP from the sensitive filter with CellSolver FBC-solution. The destructively gained samples were determined on their TVC by the conventional method. Results of the carcass-surface spray test combined with bioluminescence compared to the conventional destructive method followed by plate-count showed a correlation r=0.93 with a detection limit down to 104 cfu/cm2.
Journal title
Meat Science
Serial Year
2001
Journal title
Meat Science
Record number
1447282
Link To Document