• Title of article

    High-performance liquid chromatographic method for the quantification of unbound evernimicin in human plasma ultrafiltrate

  • Author/Authors

    Zhong، نويسنده , , Ruyun and Hernandez، نويسنده , , Abraham and Alton، نويسنده , , Kevin B. and Kishnani، نويسنده , , Narendra S. and Patrick، نويسنده , , James E.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2002
  • Pages
    5
  • From page
    191
  • To page
    195
  • Abstract
    A rapid HPLC method was developed for quantification of unbound evernimicin in human plasma. Protein-free samples prepared by ultrafiltration were injected directly onto a polymeric reversed-phase column and the eluent monitored at 302 nm. Evernimicin that eluted within 3.5 min was well resolved from endogenous components. Linearity was established between peak height and evernimicin concentration from 25 to 2500 ng/ml. Assay precision (C.V.) was within 5% while bias was no greater than 3%. This method has been used for the ex vivo assessment of evernimicin protein binding in human plasma from safety and tolerance as well as liver dysfunction and renal insufficiency studies.
  • Keywords
    Evernimicin
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2002
  • Journal title
    Journal of Chromatography B
  • Record number