Title of article :
Non-linear heteroscedastic regression model for determination of methotrexate in human plasma by high-performance liquid chromatography
Author/Authors :
Sadray، نويسنده , , Sima and Rezaee، نويسنده , , Saeed and Rezakhah، نويسنده , , Saeid، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
10
From page :
293
To page :
302
Abstract :
Generalized least squares regression with variance function estimation was used to derive the calibration function for measurement of methotrexate plasma concentration and its results were compared with weighted least squares regression by usual weight factors and also with that of ordinary least squares method. In the calibration curve range of 0.05 to 100 μM, both heteroscedasticity and non-linearity were present therefore ordinary least squares linear regression methods could result in large errors in the calculation of methotrexate concentration. Generalized least squares regression with variance function estimation worked better than both the weighted regression with the usual weight factors and ordinary least squares regression and gave better estimates for methotrexate concentration.
Keywords :
Methotrexate
Journal title :
Journal of Chromatography B
Serial Year :
2003
Journal title :
Journal of Chromatography B
Record number :