• Title of article

    Selective, sensitive and rapid liquid chromatography–tandem mass spectrometry method for the determination of alfuzosin in human plasma

  • Author/Authors

    Wiesner، نويسنده , , J.L. and Sutherland، نويسنده , , F.C.W and van Essen، نويسنده , , G.H. and Hundt، نويسنده , , H.K.L and Swart، نويسنده , , K.J and Hundt، نويسنده , , A.F، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2003
  • Pages
    8
  • From page
    361
  • To page
    368
  • Abstract
    A selective, sensitive and rapid liquid chromatography–tandem mass spectrometry method for the determination of alfuzosin in plasma was developed. A PE Sciex API 2000 triple quadrupole mass spectrometer in multiple reaction monitoring (MRM) mode, using TurboIonSpray with positive ionisation was used. Using prazosin as an internal standard, liquid–liquid extraction was followed by C18 reversed-phase liquid chromatography and tandem mass spectrometry. The mean recovery for alfuzosin was 82.9% with a lower limit of quantification set at 0.298 ng/ml, the calibration range being between 0.298 and 38.1 ng/ml. This assay method makes use of the increased sensitivity and selectivity of tandem mass spectrometric (MS–MS) detection to allow for a more rapid (extraction and chromatography) and selective method for the determination of alfuzosin in human plasma than has previously been described. The assay method was used to quantify alfuzosin in human plasma samples generated in a multiple-dose (5 mg bd.) study at steady state.
  • Keywords
    Alfuzosin
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2003
  • Journal title
    Journal of Chromatography B
  • Record number

    1455204