Title of article :
Membrane cartridges for endotoxin removal from interferon preparations
Author/Authors :
Li، نويسنده , , Jinghua and Shao، نويسنده , , Yingguang and Chen، نويسنده , , Zhaoan and Cong، نويسنده , , Runzi and Wang، نويسنده , , Junde and Liu، نويسنده , , Xueliang، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
7
From page :
55
To page :
61
Abstract :
The suitability of membrane cartridges for the removal of endotoxin from both distilled water and interferon preparations was examined. The endotoxin concentrations were reduced to 4.0 and 7.3 EU/ml, respectively, when about 4000 ml of distilled water with 20 and 28 EU/ml were passed through the deoxycholate and chitosan immobilized membrane cartridges. When 200 ml of interferon preparation with endotoxin concentration more than 80 EU/ml and pH 3.9 were applied to a deoxycholate immobilized membrane cartridge at a flow-rate of 9 ml/min, the endotoxin concentration was reduced to less than 10 EU/ml. However, if an interferon preparation of 450 ml, with more than 80 EU/ml of endotoxin and pH 3.9 was applied to the chitosan immobilized membrane cartridge at a flow-rate of 18 ml/min, the endotoxin concentration was reduced to less than 10 EU/ml.
Keywords :
Chitosan , Deoxycholate , Endotoxin , Interferon
Journal title :
Journal of Chromatography B
Serial Year :
2003