Title of article :
Sensitive determination of tenofovir in human plasma samples using reversed-phase liquid chromatography
Author/Authors :
Sentenac، نويسنده , , S. Revilla-Fernandez، نويسنده , , C. and Thuillier، نويسنده , , A. and Lechat، نويسنده , , P. and Aymard، نويسنده , , G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2003
Pages :
8
From page :
317
To page :
324
Abstract :
A new high-performance liquid chromatography assay was developed for the determination of tenofovir, a nucleotide analogue, in plasma. A solid–liquid extraction procedure was coupled with a reversed-phase HPLC system. The system requires a mobile phase containing Na2HPO4 buffer, tetrabutylammonium hydrogen sulfate and acetonitrile for different elution through a C18 column with UV detection. The method proved to be accurate, precise and linear between 10 and 4000 ng/ml. The method was applied to determine trough levels of tenofovir in 11 HIV-infected patients with virologic failure under multiple antiretroviral therapy. This method was also successfully applied to a pharmacokinetic study in an HIV infected patient with renal failure.
Keywords :
Tenofovir
Journal title :
Journal of Chromatography B
Serial Year :
2003
Journal title :
Journal of Chromatography B
Record number :
1455704