Title of article :
Simultaneous determination of a novel KDR kinase inhibitor and its N-oxide metabolite in human plasma using 96-well solid-phase extraction and liquid chromatography/tandem mass spectrometry
Author/Authors :
Xu، نويسنده , , Yang-Guang Du، نويسنده , , Lihong and Soli، نويسنده , , Eric D. and Braun، نويسنده , , Matthew P. and Dean، نويسنده , , Dennis C. and Musson، نويسنده , , Donald G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2005
Pages :
10
From page :
287
To page :
296
Abstract :
To support pharmacokinetic studies, a selective and sensitive liquid chromatography/tandem mass spectrometry (LC–MS/MS) method has been developed and validated for the simultaneous determination of a novel KDR kinase inhibitor (1) and its active metabolite (2) in human plasma. The method is fully automated using a Packard MultiPROBE II system and a TomTec Quadra 96 liquid handling workstation to perform sample preparation and solid-phase extraction (SPE). Following the extraction on a mixed-mode SPE using Oasis MCX 96-well plate, the analytes were separated on a Aquasil C18 column (50 mm × 2.1 mm, i.d., 3 μm) with a mobile phase consisting of acetonitrile/ammonium acetate buffer (5 mM, pH 5.0) (60/40, v/v). The run time for each injection was 4.5 min with the retention times of approximately 2.0 and 2.7 min for 1 and 2 respectively, at a flow rate of 0.25 mL/min. A tandem mass spectrometric detection was conducted using multiple reaction monitoring (MRM) under the positive ion mode with a turbo ion-spray interface. The linear ranges of the calibration curves were 0.05–400 ng/mL for 1 and 0.1–400 ng/mL for 2 on a PE Sciex API 4000 LC–MS/MS system. The lower limits of quantitation (LLOQ) of the assay were 0.05 and 0.1 ng/mL for 1 and 2 respectively, when 0.4 mL of plasma was processed. Intra-day assay precision (using five standard curves prepared by spiking compounds to five lots of plasma) was less than 4.9% for 1 and less than 9.6% for 2 on each concentration. Assay accuracy was found to be 95.1–104.6% of nominal for 1 standards and 93.5–105.6% for 2 standards. QC samples were stable when kept at room temperature for 4 h, at −70 °C for 10 days, and after three freeze–thaw cycles. The extraction recoveries were 80%, 83% and 84% for 1 and 2 and I.S. respectively, and no significant matrix effects were observed. The method was successfully applied to plasma samples from clinical studies after oral administration of compound 1.
Keywords :
N-Oxide metabolite , Oasis MCX solid-phase 96-well extraction plate , LC–MS/MS , KDR kinase inhibitor
Journal title :
Journal of Chromatography B
Serial Year :
2005
Journal title :
Journal of Chromatography B
Record number :
1457274
Link To Document :
بازگشت