Title of article
Determination of free ertapenem in plasma and bronchoalveolar lavage by high-performance liquid chromatography with ultraviolet detection
Author/Authors
Gordien، نويسنده , , Jean-Baptiste and Boselli، نويسنده , , Emmanuel and Fleureau، نويسنده , , Catherine and Allaouchiche، نويسنده , , Bernard and Janvier، نويسنده , , Gérard and Lalaude، نويسنده , , Olivier and Saux، نويسنده , , Marie-Claude and Breilh، نويسنده , , Dominique، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2006
Pages
6
From page
218
To page
223
Abstract
A sensitive assay for the determination of unbound ertapenem in human plasma and bronchoalveolar lavage (BAL) was developed using ultrafiltration of plasma and BAL samples. A rapid HPLC method was used with ultraviolet detection set at a wavelength of 305 nm and a separation on a Prontosil AQ C18 column, with imipenem used as internal standard. This assay was linear over the concentration range of 0.5–100 μg/mL and 0.25–50 μg/mL in plasma and BAL, respectively. Limits of detection and quantitation were respectively 0.05 and 0.25 μg/mL. Validation data for accuracy and precision were CV < 2.48 and 8.25%, accuracy in the range 98.1–104.2% and 102.2–108.4%, respectively, for intra and inter-day.
Keywords
Free ertapenem in plasma and BAL , Ultrafiltration , Pharmacokinetics , HPLC UV detection
Journal title
Journal of Chromatography B
Serial Year
2006
Journal title
Journal of Chromatography B
Record number
1462599
Link To Document