Title of article :
Column-switching high-performance liquid chromatographic method for the determination of zaltoprofen in rat plasma
Author/Authors :
Choi، نويسنده , , Sun Ok and Um، نويسنده , , So Young and Jung، نويسنده , , Sung Hee and Jung، نويسنده , , Seo Jeong and Kim، نويسنده , , Joo Il and Lee، نويسنده , , Hwa Jeong and Chung، نويسنده , , Soo Youn، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
A direct injection column-switching high-performance liquid chromatography (HPLC) method was developed and validated for quantification of zaltoprofen in rat plasma. Following dilution with mobile phase A, i.e. acetonitrile-10 mM potassium phosphate buffer (pH 6.8) (12:88, v/v) samples were directly injected to the pre-column without sample pre-purification step. After endogenous plasma components were eluted to waste, the system was switched and the analyte was eluted to the trap column. Zaltoprofen was then back-flushed to the analytical column for separation with mobile phase B, i.e. acetonitrile–10 mM potassium phosphate buffer (pH 6.8) (35:65, v/v) and quantification with an ultraviolet detector at 230 nm. The calibration curve was linear in the concentration range of 40–5000 ng mL−1. This method has been fully validated and shown to be specific, accurate and precise. The method is simple, rapid and the sample preparation is minimal and appears to be useful for the pharmacokinetic study of zaltoprofen.
Keywords :
direct injection , Rat plasma , Column switching , Zaltoprofen , High-Performance Liquid Chromatography (HPLC)
Journal title :
Journal of Chromatography B
Journal title :
Journal of Chromatography B