Title of article :
Rapid determination of valsartan in human plasma by protein precipitation and high-performance liquid chromatography
Author/Authors :
Macek، نويسنده , , J. and Kl?ma، نويسنده , , J. and Pt??ek، نويسنده , , P.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Abstract :
A high-performance liquid chromatographic (HPLC) method for the determination of valsartan in human plasma is reported. The assay is based on protein precipitation with methanol and reversed-phase chromatography with fluorimetric detection. The preparation of a batch of 24 samples takes 20 min. The liquid chromatography was performed on an octadecylsilica column (50 mm × 4 mm, 5 μm particles), the mobile phase consisted of acetonitrile −15 mM dihydrogenpotassium phosphate, pH 2.0 (45:55, v/v). The run time was 2.8 min. The fluorimetric detector was operated at 234/374 nm (excitation/emission wavelength). The limit of quantitation was 98 ng/ml using 0.2 ml of plasma. Within-day and between-day precision expressed by relative standard deviation was less than 5% and inaccuracy did not exceed 8%. The assay was applied to the analysis of samples from a pharmacokinetic study.
Keywords :
valsartan , Protein precipitation , Pharmacokinetics
Journal title :
Journal of Chromatography B
Journal title :
Journal of Chromatography B