Title of article :
HPLC determination of a novel aroylhydrazone iron chelator (o-108) in rabbit plasma and its application to a pilot pharmacokinetic study
Author/Authors :
Kova??kov?، نويسنده , , Petra and Klime?، نويسنده , , Ji?? and ?t?rba، نويسنده , , Martin and Popelov?، نويسنده , , Olga and Ger?l، نويسنده , , Vladim?r and Po?ka، نويسنده , , P?emysl، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2006
Pages :
6
From page :
107
To page :
112
Abstract :
A high performance liquid chromatographic method for the determination of a biocompatible iron chelator, pyridoxal 2-chlorobenzoyl hydrazone (o-108), in rabbit plasma was developed and validated. The separation was achieved on a C18 column with the mobile phase composed of a mixture of 0.01 M phosphate buffer (pH 6) with the addition of EDTA (2 mM), methanol and acetonitrile (42:24:14; v/v/v). The method was validated with respect to selectivity, linearity (0.8–150 μg/mL), intra- and inter-day variability and stability. This method was successfully applied to the analysis of the samples obtained from a pilot pharmacokinetic experiment, in which the chelator was administered intravenously to rabbits.
Keywords :
Pyridoxal 2-chlorobenzoyl hydrazone , HPLC , Iron chelator , o-108 , Pharmacokinetics
Journal title :
Journal of Chromatography B
Serial Year :
2006
Journal title :
Journal of Chromatography B
Record number :
1463249
Link To Document :
بازگشت