• Title of article

    Influence of vent air valve opening on combustion characteristics of a down-fired pulverized-coal 300 MWe utility boiler

  • Author/Authors

    Li، نويسنده , , Zhengqi and Ren، نويسنده , , Feng and Zhang، نويسنده , , Jie and Zhang، نويسنده , , Xiaohui and Chen، نويسنده , , Zhichao and Chen، نويسنده , , Lizhe، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2007
  • Pages
    6
  • From page
    2457
  • To page
    2462
  • Abstract
    Industrial experiments have been performed on a down-fired pulverized-coal 300 MWe utility boiler with vent air valve opening of 100% and 40%. The gas temperature distribution along the primary air and coal mixture flow, gas temperature distribution in the furnace, and gas components such as O2, CO, CO2 and NOx in the near-wall region were measured for the first time. The influence of vent air valve opening on coal combustion in the furnace was determined. The results indicate that ignition of the primary air and pulverized-coal mixture is delayed. The position of the gas temperature peak is above the arches. Emission of NOx is up to 2101 mg/m3 (at 6% O2 dry) with vent valve opening of 40%.
  • Keywords
    NOX , Down-fired boiler , cyclone
  • Journal title
    Fuel
  • Serial Year
    2007
  • Journal title
    Fuel
  • Record number

    1464282