High-performance liquid chromatographic method with UV photodiode-array, fluorescence and mass spectrometric detection for simultaneous determination of galantamine and its phase I metabolites in biological samples
Author/Authors
Mal?kov?، نويسنده , , Jana and Nobilis، نويسنده , , Milan and Svoboda، نويسنده , , Zbyn?k and L?sa، نويسنده , , Miroslav and Hol?apek، نويسنده , , Michal and Kv?tina، نويسنده , , Jaroslav and Klime?، نويسنده , , Ji?? and Pali?ka، نويسنده , , Vladim?r، نويسنده ,
Issue Information
روزنامه با شماره پیاپی سال 2007
Pages
10
From page
265
To page
274
Abstract
Galantamine, an alkaloid isolated from the bulbs and flowers of Caucasian snowdrop (Galanthus woronowii, Amaryllidaceae) and related species, is employed in human medicine for the treatment of various neuromuscular and neurodegenerative diseases. After the administration, the products of oxidative biotransformation (O-desmethyl-galantamine, N-desmethyl-galantamine, galantamine-N-oxide) and chiral conversion (epigalantamine) are formed in various concentrations from parent compound. For the identification and determination of galantamine and its phase I metabolites in blood plasma and tissues, a new bioanalytical method based on a reversed-phase high-performance liquid chromatography with UV photodiode-array, fluorescence and mass spectrometric detection was developed, validated and applied to pharmacokinetic and biotransformation studies. Sample preparation included a homogenization of the rat tissues (liver, brain, hypophysis) in a phosphate buffer 0.05 mol/L pH 7.4. Plasma samples and tissue homogenates were purified using a mixed-mode solid-phase extraction (Waters Oasis MCX cartridges). Galantamine, its above-mentioned metabolites and the internal standard codeine were separated on a Discovery HS F5 column (Supelco, 150 mm× 4.6 mm I.D., 5 μm) at flow rate of 1 mL/min using a linear gradient elution. UV photodiode-array and mass spectrometric detection were employed for the identification of individual galantamine metabolites in various biomatrices, the fluorescence detection (λexcit = 280 nm/λemiss = 310 nm) was chosen for the quantification of galantamine and its metabolites. The developed method was applicable in liver tissue in the range from 0.50 to 63.47 nmol/g of galantamine, from 0.32 to 41.42 nmol/g of O-desmethyl-galantamine, from 0.54 to 69.40 nmol/g of N-desmethyl-galantamine and from 0.70 to 89.03 nmol/g of epigalantamine. Limit of detection was found to be 0.04 nmol/g for galantamine, 0.19 nmol/g for O-desmethyl-galantamine, and 0.07 nmol/g for N-desmethyl-galantamine and epigalantamine.
Keywords
High-performance liquid chromatography , fluorescence detection , mass spectrometry , GALANTAMINE , metabolites
Journal title
Journal of Chromatography B
Serial Year
2007
Journal title
Journal of Chromatography B
Record number
1464732
Link To Document