Title of article :
Jones oxidation and high performance liquid chromatographic analysis of cholesterol in biological samples
Author/Authors :
Dong، نويسنده , , Jun and Chen، نويسنده , , Wenxiang and Wang، نويسنده , , Shu and Zhang، نويسنده , , Jiangtao and Li، نويسنده , , Hongxia and Guo، نويسنده , , Hanbang and Man، نويسنده , , Yong and Chen، نويسنده , , Baosheng، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2007
Pages :
8
From page :
239
To page :
246
Abstract :
A simple pre-column derivatization procedure for HPLC analysis of cholesterol in biological samples was developed. Cholesterol was treated with chromic acid and sulfuric acid in acetone (the Jones oxidation) and cholest-4-en-3,6-dione was formed. The reaction was finished in 5 min at room temperature and the product showed a strong UV absorbance at 250 nm that enabled an HPLC detection limit of 0.2 pmol. With stigmasterol as an internal standard, the reaction was applied to the analysis of total and free cholesterol in serum and high-density lipoproteins and the analysis showed a within-run and total coefficient of variation of about 0.2% and 0.5%, respectively.
Keywords :
Cholest-4-en-3 , 6-dione , Stigmasterol , HPLC , Cholesterol , chromic acid