• Title of article

    Validation of an HPLC/MS/MS method with isotopic dilution for quantitative determination of trans,trans-muconic acid in urine samples of workers exposed to low benzene concentrations

  • Author/Authors

    Tranfo، نويسنده , , Giovanna and Paci، نويسنده , , Enrico and Sisto، نويسنده , , Renata and Pigini، نويسنده , , Daniela، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2008
  • Pages
    6
  • From page
    26
  • To page
    31
  • Abstract
    Urinary trans,trans-muconic acid (t,t-MA), a biomarker of benzene exposure, is usually determined by HPLC methods with detection by either UV or, more recently, electrospray tandem mass spectrometry. However, not all these methods have been fully validated for quantitative analysis. This paper presents an HPLC/MS/MS method for reliable quantitative determination of t,t-MA that uses a commercial deuterium-labeled isotope as internal standard; the matrix effect has been evaluated and LOD is 0.22 μg/L. We used this method to test 200 urine samples, 175 of them collected at end-of-shift from workers in an oil refinery.
  • Keywords
    BIOLOGICAL MONITORING , trans , trans-Muconic acid , HPLC/MS/MS , Oil refinery workers , Method validation
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2008
  • Journal title
    Journal of Chromatography B
  • Record number