Title of article :
Simultaneous determination of 11 designated hallucinogenic phenethylamines by ultra-fast liquid chromatography with fluorescence detection
Author/Authors :
Min، نويسنده , , Jun Zhe and Shimizu، نويسنده , , Yoshiha and Toyo’oka، نويسنده , , Toshimasa and Inagaki، نويسنده , , Shinsuke and Kikura-Hanajiri، نويسنده , , Ruri and Goda، نويسنده , , Yukihiro، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2008
Pages :
8
From page :
187
To page :
194
Abstract :
To avoid the spreading of illegal drugs, a designated drug regulation system was introduced along with revision of the Pharmaceutical Affairs Law in Japan in 2006, and 32 substances including phenethylamine-type drugs were listed in April 2007. In this study, a new simultaneous determination method, based on ultra-fast liquid chromatography coupled with fluorescence detection (UFLC–FL), was developed for the 11 designated phenethylamine drugs. The phenethylamines were labeled with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) at 60 °C for 2 h in 0.1 M borax (pH 9.3). The resulting 11 fluorophores were completely separated by reversed-phase chromatography using an ACQUITY UPLC BEH C18 column (2.1 mm × 100 mm 1.7 μm) and fluorometrically detected at 550 nm (excitation at 450 nm). The calibration curves obtained from the peak areas versus the injection amounts of the phenethylamines showed a good linearity. The limits of detection (signal-to-noise ratio of 3: S/N = 3) on the chromatogram were in the range from 10 fmol (PMMA) to 2.5 pmol (MMDA-2). Good accuracy (%) and precision (CV) by intra-day assay and inter-day assay were also obtained using the present procedure. The method was applied to the qualitative and quantitative analyses of phenethylamine in real products obtained from the Japanese market. As the results, BDB (0.24 mg/mg), MMDA-2 (0.98 mg/mL) and 2C-I (0.016 mg/mg) were identified from the different products (powder, liquid and mushroom like). Because the procedure is simple, selective and sensitive, the present method seems to be useful for the qualitative and quantitative analyses of the designated phenethylamines in various samples including biological specimens.
Keywords :
N-Dimethylaminosulfonyl)-7-fluoro-2 , 1 , 3-benzoxadiazole , 4-(N , Ultra-fast liquid chromatography , Designated hallucinogenic phenethylamines , fluorescence labeling
Journal title :
Journal of Chromatography B
Serial Year :
2008
Journal title :
Journal of Chromatography B
Record number :
1466384
Link To Document :
بازگشت