• Title of article

    The effect of diluent on flame structure and laminar burning speeds of JP-8/oxidizer/diluent premixed flames

  • Author/Authors

    Eisazadeh-Far، نويسنده , , Kian and Moghaddas، نويسنده , , Ali and Metghalchi، نويسنده , , Hameed and Keck، نويسنده , , James C.، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2011
  • Pages
    11
  • From page
    1476
  • To page
    1486
  • Abstract
    Experimental studies have been performed to investigate the flame structure and laminar burning speed of JP-8/oxidizer/diluent premixed flames at high temperatures and pressures. Three different diluents including argon, helium, and a mixture of 14% CO2 and 86% N2 (extra diluent gases), were used. The experiments were carried out in two constant volume spherical and cylindrical vessels. Laminar burning speeds were measured using a thermodynamics model based on the pressure rise method. Temperatures from 493 to 700 K and pressures from 1 to 11.5 atm were investigated. Extra diluent gases (EDG) decrease the laminar burning speeds but do not greatly impact the stability of the flame compared to JP-8/air. Replacing nitrogen in the air with argon and helium increases the range of temperature and pressure in the experiments. Helium as a diluent also increases the temperature and pressure range of stable flame as well as the laminar burning speed. Power law correlations have been developed for laminar burning speeds of JP-8/air/EDG and JP-8/oxygen/helium mixtures at a temperature range of 493–700 K and a pressure range of 1–10 atm for lean mixtures.
  • Keywords
    Laminar burning speed , JP-8 , Diluent , Combustion instability
  • Journal title
    Fuel
  • Serial Year
    2011
  • Journal title
    Fuel
  • Record number

    1466625