Title of article :
A novel validated procedure for the determination of nicotine, eight nicotine metabolites and two minor tobacco alkaloids in human plasma or urine by solid-phase extraction coupled with liquid chromatography–electrospray ionization–tandem mass spectrometr
Author/Authors :
Miller، نويسنده , , Eleanor I. and Norris، نويسنده , , Hye-Ryun K. and Rollins، نويسنده , , Douglas E. and Tiffany، نويسنده , , Stephen T. and Wilkins، نويسنده , , Diana G.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2010
Pages :
13
From page :
725
To page :
737
Abstract :
A novel validated liquid chromatography–tandem mass spectrometry (LC–MS/MS) procedure was developed and fully validated for the simultaneous determination of nicotine-N-β-d-glucuronide, cotinine-N-oxide, trans-3-hydroxycotinine, norcotinine, trans-nicotine-1′-oxide, cotinine, nornicotine, nicotine, anatabine, anabasine and cotinine-N-β-d-glucuronide in human plasma or urine. Target analytes and corresponding deuterated internal standards were extracted by solid-phase extraction and analyzed by LC–MS/MS with electrospray ionization (ESI) using multiple reaction monitoring (MRM) data acquisition. Calibration curves were linear over the selected concentration ranges for each analyte, with calculated coefficients of determination (R2) of greater than 0.99. The total extraction recovery (%) was concentration dependent and ranged between 52–88% in plasma and 51–118% in urine. The limits of quantification for all analytes in plasma and urine were 1.0 ng/mL and 2.5 ng/mL, respectively, with the exception of cotinine-N-β-d-glucuronide, which was 50 ng/mL. Intra-day and inter-day imprecision were ≤14% and ≤17%, respectively. Matrix effect (%) was sufficiently minimized to ≤19% for both matrices using the described sample preparation and extraction methods. The target analytes were stable in both matrices for at least 3 freeze–thaw cycles, 24 h at room temperature, 24 h in the refrigerator (4 °C) and 1 week in the freezer (−20 °C). Reconstituted plasma and urine extracts were stable for at least 72 h storage in the liquid chromatography autosampler at 4 °C. The plasma procedure has been successfully applied in the quantitative determination of selected analytes in samples collected from nicotine-abstinent human participants as part of a pharmacokinetic study investigating biomarkers of nicotine use in plasma following controlled low dose (7 mg) transdermal nicotine delivery. Nicotine, cotinine, trans-3-hydroxycotinine and trans-nicotine-1′-oxide were detected in the particular sample presented herein. The urine procedure has been used to facilitate the monitoring of unauthorized tobacco use by clinical study participants at the time of physical examination (before enrollment) and on the pharmacokinetic study day.
Keywords :
Nicotine and nicotine metabolites , LC–ESI–MS/MS , 7-mg transdermal nicotine patch , Plasma/urine
Journal title :
Journal of Chromatography B
Serial Year :
2010
Journal title :
Journal of Chromatography B
Record number :
1468216
Link To Document :
بازگشت