    Development and validation of a liquid chromatography–tandem mass spectrometry method for the determination of goserelin in rabbit plasma

  • Author/Authors

    Kim، نويسنده , , Min Kyung and Lee، نويسنده , , Tae Ho and Suh، نويسنده , , Joon Hyuk and Eom، نويسنده , , Han Young and Min، نويسنده , , Jung Won and Yeom، نويسنده , , Hyesun and Kim، نويسنده , , Unyong and Jung، نويسنده , , Hyung Joon and Cha، نويسنده , , Kyung Hoi and Choi، نويسنده , , Yong Seok and Youm، نويسنده , , Jeong-Rok and Han، نويسنده , , Sang Beom، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2010
  • Pages
    8
  • From page
    2235
  • To page
    2242
  • Abstract
    A rapid and sensitive liquid chromatography–electrospray ionization tandem mass spectrometry method (LC–ESI-MS/MS) was developed and validated for the determination of goserelin in rabbit plasma. Various parameters affecting plasma sample preparation, LC separation, and MS/MS detection were investigated, and optimized conditions were identified. Acidified plasma samples were applied to Oasis® HLB solid-phase extraction (SPE) cartridges. Extracted samples were evaporated under a stream of nitrogen and then reconstituted with 100 μL mobile phase A. The separation was achieved on a Capcell-Pak C18 (2.0 mm × 150 mm, 5 μm, AQ type) column with a gradient elution of solvent A (0.05% acetic acid in deionized water/acetonitrile = 85/15; v/v) and solvent B (acetonitrile) at a flow rate of 250 μL/min. The LC–MS/MS system was equipped with an electrospray ion source operating in positive ion mode. Multiple-reaction monitoring (MRM) of the precursor–product ion transitions consisted of m/z 635.7 → m/z 607.5 for goserelin and m/z 424.0 → m/z 292.1 for cephapirin (internal standard). The proposed method was validated by assessing specificity, linearity, limit of quantification (LOQ), intra- and inter-day precision and accuracy, recovery, and stability. Linear calibration curves were obtained in the concentration range of 0.1–20 ng/mL (the correlation coefficients were above 0.99). The LOQ of the method was 0.1 ng/mL. Results obtained from the validation study of goserelin showed good accuracy and precision at concentrations of 0.1, 1, 5, 10, and 20 ng/mL. The validated method was successfully applied to a pharmacokinetic study of goserelin after a single subcutaneous injection of 3.6 mg of goserelin in healthy white rabbits.
  • Keywords
    Rabbit plasma , Pharmacokinetic study , Liquid chromatography–tandem mass spectrometry , Goserelin , Peptide
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2010
  • Journal title
    Journal of Chromatography B
  • Record number

    1468697