Title of article :
A high-throughput U-HPLC–MS/MS assay for the quantification of mycophenolic acid and its major metabolites mycophenolic acid glucuronide and mycophenolic acid acyl-glucuronide in human plasma and urine
Author/Authors :
Dorota Klepacki، نويسنده , , Jacek and Klawitter، نويسنده , , Jelena and Bendrick-Peart، نويسنده , , Jamie and Schniedewind، نويسنده , , Bjorn and Heischmann، نويسنده , , Svenja and Shokati، نويسنده , , Touraj and Christians، نويسنده , , Uwe and Klawitter، نويسنده , , Jost، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
7
From page :
113
To page :
119
Abstract :
Mycophenolic acid (MPA) is used as an immunosuppressant after organ transplantation and for the treatment of immune diseases. There is increasing evidence that therapeutic drug monitoring and plasma concentration-guided dose adjustments are beneficial for patients to maintain immunosuppressive efficacy and to avoid toxicity. The major MPA metabolite that can be found in high concentrations in plasma is MPA glucuronide (MPAG). A metabolite usually present at lower concentrations, MPA acyl-glucuronide (AcMPAG), has been implicated in some of the adverse effects of MPA. We developed and validated an automated high-throughput ultra-high performance chromatography–tandem mass spectrometry (U-HPLC–MS/MS) assay using liquid-handling robotic extraction for the quantification of MPA, MPAG, and AcMPAG in human EDTA plasma and urine. The ranges of reliable response were 0.097 (lower limit of quantitation) to 200 μg/mL for MPA and MPAG and 0.156–10 μg/mL for AcMPAG in human urine and plasma. The inter-day accuracies were 94.3–104.4%, 93.8–105.0% and 94.4–104.7% for MPA, MPAG and AcMPAG, respectively. Inter-day precisions were 0.7–7.8%, 0.9–6.9% and 1.6–8.6% for MPA, MPAG and AcMPAG. No matrix interferences, ion suppression/enhancement and carry-over were detected. The total assay run time was 2.3 min. The assay met all predefined acceptance criteria and the quantification of MPA was successfully cross-validated with an LC–MS/MS assay routinely used for clinical therapeutic drug monitoring. The assay has proven to be robust and reliable during the measurement of samples from several pharmacokinetics trials.
Keywords :
Mycophenolic acid , Mycophenolic acid glucuronide , Mycophenolic acid acyl-glucuronide , U-HPLC–MS/MS , immunosuppressant
Journal title :
Journal of Chromatography B
Serial Year :
2012
Journal title :
Journal of Chromatography B
Record number :
1469541
Link To Document :
بازگشت