Title of article :
Development and validation of LC–MS/MS assays for the quantification of E7080 and metabolites in various human biological matrices
Author/Authors :
Tom M. A. R. Dubbelman، نويسنده , , A.C. and Rosing، نويسنده , , J. H. H. Thijssen، نويسنده , , B. and Gebretensae، نويسنده , , A. and Lucas، نويسنده , , L. and Chen، نويسنده , , H. and Shumaker، نويسنده , , R. and Schellens، نويسنده , , J.H.M. and Beijnen، نويسنده , , J.H.، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
10
From page :
25
To page :
34
Abstract :
To support clinical pharmacokinetic studies with the anticancer agent E7080 (lenvatinib), liquid chromatography tandem mass spectrometry (LC–MS/MS) methods were developed for the quantification of E7080 and four of its metabolites in human plasma, urine and faeces and of E7080 in whole blood. Cross-analyte interferences between metabolites and parent compound were expected and therefore accounted for early in the method development. Plasma, urine and faeces samples were extracted with acetonitrile. Chromatographic separation was achieved on a 50 mm × 2.1 mm I.D. XTerra MS C18 column, with a 0.2 mL/min flow and gradient elution starting with 100% formic acid in water, followed by an increasing percentage of acetonitrile. Whole blood samples were extracted with diethyl ether and extracts were injected on a 150 mm × 2.1 mm I.D. Symmetry Shield RP8 column. Detection was performed using an API3000 triple quadrupole mass spectrometer, with a turbo ion spray interface, operating in positive ion mode. Using 250 μL of plasma, E7080 and its metabolites could be quantified between 0.25 and 50.0 ng/mL. The quantifiable ranges of E7080 in whole blood, urine and faeces were 0.25–500 ng/mL, 1.00–500 ng/mL and 0.1–25 μg/g, using sample volumes of 250 μL, 200 μL and 250 mg, respectively. Calibration curves in all matrices were linear with a correlation coefficient (r2) of 0.994 or better. At the lower limit of quantification, accuracies were within ±20% of the nominal concentration with CV values less than 20%. At the other concentrations the accuracies were within ±15% of the nominal concentration with CV values below 15%. The developed methods have successfully been applied in a mass balance study of E7080.
Keywords :
metabolites , LC–MS/MS , Biological matrices , Cross-analyte interference , E7080
Journal title :
Journal of Chromatography B
Serial Year :
2012
Journal title :
Journal of Chromatography B
Record number :
1469681
Link To Document :
بازگشت