Title of article :
Automated multi-step purification protocol for Angiotensin-I-Converting-Enzyme (ACE)
Author/Authors :
Eisele، نويسنده , , Thomas and Stressler، نويسنده , , Timo and Kranz، نويسنده , , Bertolt and Fischer، نويسنده , , Lutz، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2012
Pages :
7
From page :
64
To page :
70
Abstract :
Highly purified proteins are essential for the investigation of the functional and biochemical properties of proteins. The purification of a protein requires several steps, which are often time-consuming. In our study, the Angiotensin-I-Converting-Enzyme (ACE; EC 3.4.15.1) was solubilised from pig lung without additional detergents, which are commonly used, under mild alkaline conditions in a Tris–HCl buffer (50 mM, pH 9.0) for 48 h. An automation of the ACE purification was performed using a multi-step protocol in less than 8 h, resulting in a purified protein with a specific activity of 37 U mg−1 (purification factor 308) and a yield of 23.6%. The automated ACE purification used an ordinary fast-protein-liquid-chromatography (FPLC) system equipped with two additional switching valves. These switching valves were needed for the buffer stream inversion and for the connection of the Superloop™ used for the protein parking. Automated ACE purification was performed using four combined chromatography steps, including two desalting procedures. The purification methods contained two hydrophobic interaction chromatography steps, a Cibacron 3FG-A chromatography step and a strong anion exchange chromatography step. The purified ACE was characterised by sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) and native-PAGE. The estimated monomer size of the purified glycosylated ACE was determined to be ∼175 kDa by SDS-PAGE, with the dimeric form at ∼330 kDa as characterised by a native PAGE using a novel activity staining protocol. For the activity staining, the tripeptide l-Phe-Gly-Gly was used as the substrate. The ACE cleaved the dipeptide Gly-Gly, releasing the l-Phe to be oxidised with l-amino acid oxidase. Combined with peroxidase and o-dianisidine, the generated H2O2 stained a brown coloured band. This automated purification protocol can be easily adapted to be used with other protein purification tasks.
Keywords :
Automated multi-step purification , Angiotensin-I-Converting-Enzyme (ACE) , Solubilisation of ACE , Activity staining of ACE
Journal title :
Journal of Chromatography B
Serial Year :
2012
Journal title :
Journal of Chromatography B
Record number :
1470705
Link To Document :
بازگشت