Title of article :
Determination of phenylephrine in human plasma using ultra-performance liquid chromatography–tandem mass spectrometry
Author/Authors :
Feng، نويسنده , , Sheng and Zhao، نويسنده , , Qian-Tao Jiang، نويسنده , , Ji and Hu، نويسنده , , Pei، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
5
From page :
28
To page :
32
Abstract :
This paper described a sensitive and rapid method based on ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC–MS/MS) for the determination of phenylephrine in human plasma. Plasma samples were pre-purified by solid-phase extraction (SPE). The chromatographic separation was achieved with BEH HILIC column using a mixture of 10 mM pH 3.5 ammonium formate and acetonitrile (10:90, v/v) under isocratic conditions at a flow rate of 0.4 mL/min. The mass spectrometry was carried out using positive electrospray ionization (ESI) and data acquisition was carried out in the multiple reaction monitoring (MRM) mode. The method was fully validated over the concentration range of 10.0–5000 pg/mL. The lower limit of quantification (LLOQ) was 10.0 pg/mL. Inter- and intra-batch precision was less than 15% and the accuracy was within 85–115%. Extraction recovery was 78.5%. Selectivity, matrix effects and stability were also validated. The method was applied to the pharmacokinetic study of phenylephrine hydrochloride in Chinese subjects.
Keywords :
Determination , Phenylephrine , UPLC–MS/MS , Human plasma
Journal title :
Journal of Chromatography B
Serial Year :
2013
Journal title :
Journal of Chromatography B
Record number :
1470809