• Title of article

    Determination of gemcitabine and its metabolite in extracellular fluid of rat brain tumor by ultra performance liquid chromatography–tandem mass spectrometry using microdialysis sampling after intralesional chemotherapy

  • Author/Authors

    Sun، نويسنده , , Ying and Tang، نويسنده , , Daoquan and Chen، نويسنده , , Hui and Zhang، نويسنده , , Fan Xitao & Fan Xiaotao ، نويسنده , , Bin and Zhang، نويسنده , , Bei and Fang، نويسنده , , Shaoying and Lu، نويسنده , , Qian and Wei، نويسنده , , Yaqin and Yin، نويسنده , , Jiale and Yin، نويسنده , , Xiaoxing، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    10
  • From page
    10
  • To page
    19
  • Abstract
    The cytotoxic agent Gemcitabine (2′,2′-difluoro-2′-deoxycytidine) has been proved to be effective in the treatment of malignant gliomas. A rapid, sensitive and specific ultra performance liquid chromatography with tandem mass spectrometry (UPLC–MS/MS) assay using microdialysis sampling was developed and validated to quantify gemcitabine and its major metabolite 2′,2′-difluoro-2′-deoxyuridine (dFdU) in Sprague–Dawley rat bearing 9 L glioma. Microdialysis probes were surgically implanted into the area of rat brain tumor in the striatal hemisphere, and artificial cerebrospinal fluid was used as a perfusion medium. The samples were analyzed directly by UPLC–MS/MS after the addition of 5-bromouracil as an internal standard (IS). Separation was achieved on Agilent SB-C18 (50 mm × 2.1 mm I.D., 1.8 μm) column at 40 °C using an isocratic elution method with acetonitrile and 0.1% formic acid (4:96, v/v) at a flow rate of 0.2 mL/min. Detection was performed using electrospray ionization in positive ion selected reaction monitoring mode by monitoring the following ion transitions m/z 264.0 → 112.0 (gemcitabine), m/z 265.1 → 113.0 (dFdU) and m/z 190.9 → 173.8 (IS). The calibration curves of gemcitabine and dFdU were linear in the concentration range of 0.66–677.08 ng/mL and 0.31–312.00 ng/mL, respectively. The lower limit of quantification of gemcitabine and dFdU were 0.66 ng/mL and 0.31 ng/mL, respectively. The lower limit of detection of gemcitabine and dFdU were calculated to be 0.2 ng/mL and 0.1 ng/mL, respectively. All the validation data, such as intra- and inter-day precision, accuracy, selectivity and stability, were within the required limits. The validated method was simple, precise and accurate, which was successfully employed to determinate the concentrations of gemcitabine and dFdU in the extracellular fluid of rat brain tumor.
  • Keywords
    microdialysis , Extracellular fluid , Gemcitabine , 2? , 2?-Difluoro-2?-deoxyuridine , UPLC–MS/MS
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2013
  • Journal title
    Journal of Chromatography B
  • Record number

    1470864