Title of article :
Evaluation of mixed-mode chromatographic resins for separating IgG from serum albumin containing feedstock
Author/Authors :
Wang، نويسنده , , Rong-Zhu and Lin، نويسنده , , Dong-Qiang and Tong، نويسنده , , Hong-Fei and Lu، نويسنده , , Hui-Li and Yao، نويسنده , , Shan-Jing، نويسنده ,
Issue Information :
روزنامه با شماره پیاپی سال 2013
Pages :
9
From page :
33
To page :
41
Abstract :
Mixed-mode chromatography has been focused as a cost-effective new technique for antibody purification. In this study, four mixed-mode resins with N-benzyl-N-methyl ethanol amine, 2-benzamido-4-mercaptobutanoic acide, 4-mercapto-ethyl-pyridine and phenylpropylamine as the ligands were tested and the multi-functional interactions between ligand and protein were discussed. Immunoglobulin G (IgG), bovine serum albumin (BSA) and the binary mixture of BSA and IgG were used as the model feedstock to compare the separation behaviors by pH gradient elution. The comparison analysis showed mixed-mode resin with N-benzyl-N-methyl ethanol amine as the ligand had the best ability to separate IgG and BSA. The results indicated that for four resins tested ionic interaction might play the dominant role in the separation of IgG and BSA while the hydrophobic interactions and hydrogen bonding have some subsidiary effects. The pH stepwise elution and sample loading were optimized to improve the IgG purification from serum albumin containing feedstock. High purity (92.3%) and high recovery (95.6%) of IgG were obtained. The results indicated that mixed-mode chromatography would be a potential option for antibody purification with the control of loading and elution conditions.
Keywords :
Mixed-mode chromatography , Serum albumin , immunoglobulin G , Gradient elution , Step elution , Purification
Journal title :
Journal of Chromatography B
Serial Year :
2013
Journal title :
Journal of Chromatography B
Record number :
1471461
Link To Document :
بازگشت