• Title of article

    Development and validation of a new UPLC-PDA method to quantify linezolid in plasma and in dried plasma spots

  • Author/Authors

    Baietto، نويسنده , , Lorena and D’Avolio، نويسنده , , Antonio and Ariaudo، نويسنده , , Alessandra and Corcione، نويسنده , , Silvia and Simiele، نويسنده , , Marco and Cusato، نويسنده , , Jessica and Urbino، نويسنده , , Rosario and Di Perri، نويسنده , , Giovanni and Ranieri، نويسنده , , V. Marco and De Rosa، نويسنده , , Francesco Giuseppe and Donato، نويسنده ,

  • Issue Information
    روزنامه با شماره پیاپی سال 2013
  • Pages
    6
  • From page
    42
  • To page
    47
  • Abstract
    Linezolid is an oxazolidinone antibiotic used for the treatment of pneumonia and uncomplicated and complicated skin and soft tissues infections caused by Gram positive bacteria. It is also used as second line agent in multi-drug resistant tuberculosis. Therapeutic drug monitoring (TDM) of linezolid represents a valid tool in clinical practice to optimize therapy, especially in critically ill patients. Spreading of TDM is mainly limited by high costs shipment and lack of laboratories that offer a TDM service. To overcome these problems, the use of dried plasma spots or dried blood spots is increasing. The aim of this work was to develop and validate a new chromatographic method to analyze linezolid in plasma and in dried plasma spots and to evaluate the correlation between the two extraction methods. Linezolid extraction from plasma and from dried plasma spots was obtained using acetonitrile. Quinoxaline was used as internal standard. Analysis was performed by an ultra performance liquid chromatography (UPLC) system coupled with photo diode array (PDA) detector, at 254 nm. Both analytical methods were linear (r2 > 0.999) over the calibration range of 30–0.117 mg/L. Limit of quantification and limit of detection were 0.117 mg/L and 0.058 mg/L, respectively. Intra and inter-day precision (R.S.D.%) and accuracy (%) were <15%. Long term stability of linezolid in dried plasma spots showed absence of degradation at room temperature (20–25 °C) and at 4 °C, for at least one month. Linear regression analysis confirmed that the two methods of extraction have good correlation. Thus they are suited for TDM of linezolid and for pharmacokinetic studies.
  • Keywords
    Linezolid , HPLC , UPLC , stability , Human plasma , Therapeutic drug monitoring TDM , Dried plasma spots
  • Journal title
    Journal of Chromatography B
  • Serial Year
    2013
  • Journal title
    Journal of Chromatography B
  • Record number

    1471465